Detailed Course Outline
Module 1: NetApp SAN Architectures
Lecture Length: 60 minutes 
Exercise Length:  30 minutes 
Module Objective #1: Explain the difference between SAN and NAS 
Module Objective #2: Describe how SCSI protocols are used within SAN 
Module Objective #3: List the SAN supported procucts in the NetApp portfolio 
 
Module Topics: 
 
The NetApp Portfolio 
- Platforms
- Hardware Universe (HWU)
- Interoperability Matrix Tool (IMT)
 
NAS and SAN Protocols 
- NAS and SAN
- Protocols used by NetApp
- SCSI
SAN Terms 
- Basic terms (Host=Initiator, Storage=Target, LUN)
- Adapters (Initiator and Target)
FC SAN 
- Nodes (WWNN)
- Ports (WWPN)
IP SAN 
- Nodes (IQN)
- Ports (portal groups)
Connectivity 
- Direct
- Switched
- Considerations (Ethernet network, fabric)
- FC Zoning
Multipath I/O 
- ALUA
- Path Selection
- Failver considerations
NetApp Hybrid SAN Portfolio 
- FAS with Data ONTAP
- E-Series with SANtricity
- Hybrid Flash Technologies
NetApp All-Flash SAN Portfolio 
- AFF with Data ONTAP
- EF-Series with SANtricity
- FlashRay with Mars
Exercise – Using the Interoperability Matrix Tool ( IMT) 
Knowledge Check  
 
Module 2: NetApp Storage Architectures
Total Lecture Length: 60 minutes 
Total Exercise Length:  10 minutes 
Module Objective #1: Describe storage architectures for Data ONTAP, SANtricity, and Mars operating systems 
Module Objective #2: Describe the Data ONTAP, SANtricity, and Mars operating system design points that are optimized for differing data workloads 
Module Objective #3:  List the management and data protection software available for Data ONTAP, SANtricity, and Mars operating systems 
 
Module Topics: 
 
Storage Architecture 
- Data ONTAP
- Storage Architecture Stack (disks > RAID groups > aggregates > FlexVol volumes > LUNs)
- Aggregate: pool on RAID
- Unified Storage Architecture (dynamic)
- RAID Levels: RAID-DP and RAID-4
 
- SANtricity 
- Traditional RAID
- Storage Architecture Stack (disks > volume groups > volumes/LUNs)
- Storage Architecture (static)
- RAID Levels: 0, 1, 10, 5, 6 (also 3)
 
- Dynamic Disk Pools 
- Storage Architecture Stack (disks > DDP > volumes/LUNs)
- DDP: RAID in the pool
- Storage Architecture (dynamic)
- DDP key concepts (D-Stripes, D-Pieces, volumes, reconstruction)
 
- Traditional RAID vs DDP
 
- Traditional RAID
- Mars OS
- Storage Architecture Stack (disks > extent store > LUNs)
- Extent store: RAID in the pool
- Storage Architecture (dynamic)
 
Performance 
- What is performance?
- IOPS
- Throughput
 
- Data ONTAP
- SANtricity
- Mars
Management Software 
- Data ONTAP: CLI, OnCommand Suite, AutoSupport
- SANtricity: SMcli, SANtricity Storage Manager, AutoSupport
- Mars: CLI, FlashRay System Manger
Data Protection 
- What is Data Protection?
- Data Protection Solutions
- Protecting SAN data
Exercise – Login to the lab environment 
Knowledge Check 
  
Module 3: FAS SANs
Lecture Length: 60 minutes 
Exercise Length:  0 minutes 
Module Objective #1: Describe the FAS configurations and architecture 
Module Objective #2: Discuss failover and giveback in FAS SAN environment 
Module Objective #3: Discuss SAN software and tools 
Module Objective #4: Describe ONTAP Features 
Module Objective #5: Briefly describe data protection and disaster recovery features 
 
Module Topics: 
 
FAS Architecture: 
- Configurations: Single-node, Multi-node, Metrocluster for Clusters
- WAFL
- Data Access
FAS failover and giveback 
- Path Failure
- Node Failure
- Giveback
- Path change (LUN Mobility)
SAN software and tools 
- OnCommand Software Suite
- Host Utilities
- Data ONTAP DSM
- SnapDrive and Snap Manager
Data ONTAP Features 
- Thin Provisioning
- Deduplication
- Compression
- LUN Mobility
Data Protection and Disaster Recover software 
- Snapshot Technologies
- SnapVault
- SnapMirror
- FlexClone
Knowledge Check 
  
Module 4: FAS SAN Implementation Overview
Module Length: 45 minutes 
Exercise Length:  60 minutes 
Module Objective #1: Describe the configuration steps to configure a FAS SAN 
Module Objective #2:  Install the Data ONTAP simulator 
 
Module Topics: 
 
Describe steps to implement SAN for Data ONTAP (both clustered ONTAP and 7-Mode) 
- Licensing or verifying the protocol
- Creating or designating a data aggregate
- Creating or designating a storage virtual machine (SVM)
- Creating, configuring, or designating ports and logical interfaces (LIFs)
- Broadcast domain and subnet review
 
- Configure the fabric (if applicable)
- zoning
 
- Creating or designating a data volume
- Creating a LUN
- Recommended Volume and LUN configurations
 
- Creating or designating an initiator group (igroup)
- Mapping the LUN to an igroup
- SLM
 
- Finding the LUN on the host and preparing the disk
Data ONTAP Simulator 
- Installing
- Capabilities and Limitations
Exercise (Windows 2012 R2, two-node cluster, iSCSI) 
Knowledge Check 
  
Module 5: SANtricity SANs
Module Length: 60 minutes 
Exercise Length:  0 minutes 
Module Objective #1: Briefly describe the E-Series configurations and architecture 
Module Objective #2: Discuss failover and giveback in E-Series SAN environment 
Module Objective #3: Discuss SAN software and tools  
Module Objective #4: Describe SANtricity Features 
Module Objective #5: Briefly describe data protection and disaster recovery software 
 
Module Topics: 
 
E-Series architecture and configurations 
- Simplex and Duplex Configuration
- Host and drive side
- Use of disks
- Volumes and LUNs
- Host and drive side write and read request
- Active/Active on host side with LVM
- Scale capacity
Failover and Failback 
- Multipath Drivers (RDAC/TPGS/ALUA)
- Explicit and Implicit failover modes
- Alternate controller detection
- Failback
SAN software and tools 
- SANtricity Storage Manager and components
- SANtricity DSM
 
- Application Integration
- Provider, APIs and Utilities
- Host Utilities
 
SANtricity Features 
- Thin privisioning
- SSD Cache
Protection Features 
- Data Assurance
- Encrypted Drives
- Snapshot Copy
- Volume Copy
- Remote Mirroring
Knowledge Check 
  
Module 6: SANtricity Implementation Overview
Module Length: 45 minutes 
Exercise Length:  60 minutes 
Module Objective #1: Describe the configuration steps to configure a E-Series SAN 
Module Objective #2:  Install the SANtricity simulator 
 
Module Topics: 
 
Configuring an Array Overview 
- Licensing premium features (if applicable)
- Configuring interfaces
- Onboard and HICs
 
- Configure the fabric (if applicable)
- FC Zoning
 
- Creating or designating a disk pool or volume group (VG)
- Creating a volume
- Peferred Controller
 
- Creating storage partitions
- Hosts and Host Groups
 
- Mapping the volume to a host or host group
- Discovering the LUN on the attached host
Simulator 
- Installing
- Capabilities and Limitations
Exercise with SANtricity simulator 
Knowledge Check 
  
Module 7: FlashRay with Mars “Preview”
Total Lecture Length: 30 minutes 
Total Exercise Length: 0 minutes 
Module Objective #1: Briefly describe the FlashRay configurations and architecture 
Module Objective #2: Describe Mars Features 
Module Objective #3: Describe the configuration steps to configure a FlashRay SAN 
 
Module Topics: 
 
FlashRay architecture and configurations 
- Single node
- 16-Gb FC
- Service Disk – PCIe Slot 1
FlashRay Software 
Mars Features 
- Thin Provisioning
- Inline Deduplication
- Inline Compression
Configuring an Array Overview 
- Configure the fabric (if applicable)
- FC Zoning
 
- Create a LUN
- Creating or designating an initiator group (igroup)
- Mapping the LUN to an igroup
- Discovering the LUN on the attached host
Exercise – case study or simulator if available 
Knowledge Check 
  
Module 9: NetApp SAN Solutions
Module Length: 30 minutes 
Exercise Length:  60 minutes 
Module Objective #1: Describe target workloads for FAS, E-Series, EF-Series and FlashRay SANs 
Module Objective #2: Discuss Positioning information for FAS, E-Series, EF-Series and FlashRay SANs 
Module Objective #3: Describe basic sizing tools 
Module Objective #4: Explain basic data migration and tools available for SAN environments 
 
Module Topics: 
 
The NetApp Portfolio 
- Positioning
- FAS/Clustered Data ONTAP
- E-Series/SANtricity
- Flash Arrays: AFF, EF-Series, FlashRay
 
- Differenciating
- Data ONTAP vs E-Series
- E-Series vs Flash
 
- Use Cases
- FAS/Data ONTAP
- E-Series/SANtricity
- Flash
 
- Customer Requirements
- When To Deploy
Sizing 
- SPM information
- E-Series Power/Cooling Calculator
- Flashray?
Data Migration Considerations 
- Terms and workflow
- Homogeneous (7-mode to cDOT 8.3)
- 7MTT
 
- Heterogenous (3rd-party or E-Series to cDOT 8.3)
- Appliance-based (FLI and DTA2800)
- Host-based
 
Exercise – Case Study 
Knowledge Check 
  
Appendix A: V-Series and FlexArray SANs
NOTE: Combines V-Series modules for Architecting SAN 
Module Objective #1: Describe the V-Series and FlexArray Virtualization Software solutions 
Module Objective #2: List the supported arrays and topologies 
Module Objective #3: Describe the NetApp recommended best practices for fabric and array maintenance  
Module Objective #4: Discuss deployment strategies for V-Series and FlexArray 
 
Module Topics: 
 
V-Series Overview 
- Unified Multivendor Storage
- Benefits
- Supported Arrays
Storage Arrays 
- Components
- Array Types
- Topologies
V-Series and E-Series 
V-Series Pre-Installation Planning 
V-Series Deployment 
Knowledge Check 
  
Appendix B: Data Migration for SAN
Module Objective #1: Describe 7-mode to cDOT SAN migrations 
Module Objective #2: Describe Foreign LUN Import feature 
 
Module Topics: 
 
- 7-mode to clustered Data ONTAP 8.3 Data Migration
- 7MTT 2.0
 
- Foreign LUN Import (FLI) in clustered Data ONTAP 8.3
- Supported arrays
- Offline migration
- Online migration (future)
 
Knowledge Check 
 
